Niehues G., Brosi M., Briindermann E., Casclle M., Funkncr S., Kehrer B., Nasse M.J., Patil M., Rota L., Steinmann J.L., Weber M., Muller A.-S.

in International Conference on Infrared, Millimeter, and Terahertz Waves, IRMMW-THz, 2018-September (2018), 8510133. DOI:10.1109/IRMMW-THz.2018.8510133

Abstract

© 2018 IEEE. A key bottleneck for investigations of ultrafast processes is a detection scheme to record all individual spectra with high repetition rates to avoid averaging and to improve the signal-to-noise ratio. Here, we present spectral measurements of fs laser sources used for electro-optical detection with a KIT-developed linear sensor array and DAQ system adapted to light sources with MHz repetition rates. This system can be equipped with different sensor types covering a broad wavelength range. It can therefore be used for various applications and scientific questions. The presented exemplary applications range from accelerator-based diagnostics to table-top laser experiments.